General Requirements
a) The equipment must be in line with ASTM G65-2004
standard specifications.
b) Weight in Kgs. should be embossed on each unit of load c) One spare nozzle shall be supplied
d) Separate bag for dust collection has to be provided
e)Doors opening either in the middle or from the top. The door should be fitted with suitable transparent windows.
f)Suitable wire mesh shall be provided at the top of hopper
to arrest foreign particles
g) 10 Nos. of standard samples ( AISI D2 tool steel or equivalent) to be provided for calibration purpose. The
volume loss range of standard specimen must be in the range of 36 ± 5 mm3.
h) 5 Nos. of rubber lined MS wheels to be supplied alongwith the equipment